Does a Tenant Need Its Own Fire Safety Plan?
A national perspective on tenant, base-building and shared Fire Safety Plan responsibilities in Canada
Dylan Dufort
August 2026 • Fire Plan Strategies
Topic
Tenant & Base-Building Plans
Focus
Code & AHJ Expectations
Perspective
Canadian Jurisdictions
A restaurant operates inside a shopping centre that already has an approved Fire Safety Plan. Does the restaurant need another one?
What about a two-storey retailer? A 2,500-square-foot dental office? A 900-square-foot nail salon? Or a major retailer occupying more than 100,000 square feet of a regional shopping centre?
After preparing Fire Safety Plans across Canada, we have learned that the word “tenant” does surprisingly little to answer the question.
The applicable Fire Code matters. The occupancy matters. The building matters. The systems and hazards matter. The relationship with the base-building Fire Safety Plan matters. The division of responsibilities between landlord and tenant can matter. And the expectations of the local authority having jurisdiction, or AHJ, matter.
Start by removing the landlord
One of the most useful ways to approach the question is to temporarily pretend the landlord does not exist.
Take the tenancy out of the shopping centre and imagine it as a standalone building with the same occupancy, occupant load, operations, hazards and fire-protection features. Would that building require a Fire Safety Plan under the applicable provincial Fire Code?
Ontario provides a useful illustration. Division B, Sentence 2.8.1.1.(1) of the Ontario Fire Code applies Section 2.8 to, among other occupancies, business and personal services occupancies where the occupant load exceeds 300 and mercantile occupancies where the occupant load exceeds 300. Other triggers apply to other occupancies, buildings and premises.
A 900-square-foot nail salon will normally present a very different Section 2.8 analysis from a large retailer with hundreds of occupants. A modest dental office may not independently trigger the applicable requirements. A large mercantile occupancy may. A restaurant can introduce different occupancy, fire-protection and operational considerations again.
The precise answer still depends on the applicable provincial or territorial requirements. But the exercise gives us a useful starting point.
In our experience, we have not encountered an AHJ requiring a small commercial tenancy to maintain its own Fire Safety Plan simply because it happens to be located inside a building requiring one. We have also encountered AHJs questioning why a plan was created for a small tenancy that would not independently have triggered the requirement.
Conversely, where the characteristics of a tenancy would independently trigger Fire Safety Plan requirements, its location inside somebody else’s building does not make those underlying fire-safety considerations disappear.
But there is an important distinction hidden inside that statement.
A tenancy requiring fire safety planning does not necessarily mean the tenant requires a completely independent Fire Safety Plan.
One building can contain several responsible parties
Consider a restaurant inside a shopping centre.
The restaurant controls its employees, its operations, its commercial cooking equipment and many of the hazards created by its business. The building owner or manager may control the central fire alarm system, sprinkler infrastructure, fire pump, emergency generator, common exits and other shared systems.
Some equipment sits awkwardly between those categories.
A fire alarm detector may be physically located above the restaurant dining room but form part of a building-wide addressable fire alarm system maintained exclusively by the landlord’s contractor. Emergency lighting may be located entirely within the tenant space while its installation and ongoing maintenance responsibilities depend on the lease and building arrangements. A rated fire separation may form the boundary between two independently operated tenancies.
Neither does the word “tenant.”
The Fire Code may not be the only document that matters
The Fire Code establishes regulatory requirements. It does not necessarily tell us how a sophisticated commercial landlord and tenant have allocated every operational and financial responsibility between themselves.
Commercial leases commonly address compliance with applicable laws, maintenance, tenant improvements, alterations to building systems, landlord access, inspections, notification requirements and the ability of the landlord to correct tenant defaults.
City of Toronto commercial lease documents provide an interesting example. In one published lease template, the landlord is responsible for specified fire-protection systems and their inspection and testing, while the tenant is required to comply with applicable fire-prevention requirements, cooperate in addressing Fire Services deficiencies and, where required by the Ontario Fire Code, develop and implement a Fire Safety Plan at the tenant’s cost. The lease also requires information to move between the parties, including fire-incident reporting and access to fire-safety compliance records.
That arrangement illustrates something important. The landlord can retain oversight and responsibility for building systems without performing every tenant obligation. The tenant can have direct responsibilities without assuming responsibility for every base-building system serving its premises.
Knowing about a system is not the same as maintaining it
Take a fire pump.
A restaurant may depend on a base-building fire pump for the sprinkler protection serving its premises. But the restaurant manager may have no access to the pump room, no authority to retain the pump contractor, no maintenance records and no authority to operate or shut down the equipment.
Does the restaurant’s Fire Safety Plan need to recognize what happens if sprinkler protection is impaired? Potentially, yes.
Does that necessarily mean the restaurant should be assigned the detailed inspection, testing, maintenance and shutdown responsibilities for the fire pump? That is a different question.
A tenant may need information about a base-building system because that system affects its emergency procedures without needing to reproduce every detail of the landlord’s responsibilities for that system.
The reverse can also be true. A building owner may need to know that a tenant has introduced a commercial cooking operation, changed an exit arrangement or altered a fire-protection interface even though the owner does not operate the tenant’s business.
Vancouver has formally recognized the coordination problem
Vancouver Fire Rescue Services addressed this issue directly in Bulletin 2026-001-FI, dated April 2, 2026.
The bulletin supersedes Bulletin 2020-003-FI and was issued to provide clarity for developments that may include multiple buildings or towers with shared fire-protection systems, or that involve air-space parcels. VFRS specifically identifies the potential for confusion when different portions of an interconnected development develop Fire Safety Plans in isolation.
For developments within the bulletin’s scope, one master Fire Safety Plan must be developed and approved before occupancy of any part of the development, with one named Fire Safety Director responsible for the entire site. Individual components or towers may then have their own Fire Safety Plans, provided they align with the master plan. Commercial retail units may similarly have their own Fire Safety Plans, provided they align with the component plan.
The wording around the commercial retail unit is particularly interesting.
That brings us back to an important distinction: when does a tenancy need to be specifically addressed by fire safety planning, and when does that require a separate tenant document?
Vancouver’s framework is also valuable because it recognizes that the shared systems need an organizing level. The master Fire Safety Plan must include site-wide fire and life-safety systems supporting the first area intended for occupancy, including examples such as the fire alarm system, sprinklers and standpipe, fire department connections, fire pump and emergency generator.
In an air-space subdivision, VFRS also requires one parcel, usually the remainder parcel, to retain responsibility for coordinating emergency procedures and ensuring the requisite inspection, testing and maintenance of fire-protection systems throughout the site.
That is a meaningful step toward answering who coordinates shared systems. It still does not prescribe every detail that belongs in each layer of the plan hierarchy.
How deeply should the master plan reach into a tenancy?
Vancouver’s current Fire Safety Plan template adds another important piece. It says unit layouts are required for business and commercial buildings, and its floor-plan requirements identify fire-safety features such as exits, fire alarm pull stations, fire alarm devices, extinguishers, emergency lighting, sprinkler valves, standpipe valves and evacuation routes.
Now consider the scale of one of Canada’s largest shopping centres, with hundreds of independently operated tenant spaces.
When the master Fire Safety Plan for a property of that size is prepared or updated, how deeply should it reach into the individual tenancies?
- Tenant boundaries?
- Occupancy or use?
- Exits?
- Internal layouts?
- Fire alarm devices?
- Emergency lighting?
- Portable extinguishers?
- Tenant-specific suppression systems?
- Evacuation routes?
Now consider a large retailer within that property that independently requires fire safety planning and has its own Fire Safety Plan. How much information should appear in both documents?
Vancouver tells us that interconnected plans need to align. Its bulletin does not provide a detailed content-allocation matrix explaining exactly what “aligned” means, how much information should be duplicated, or which document should be treated as the authoritative source for every category of information.
That does not make the framework incomplete for its purpose. It means that applying the framework to a real property still requires decisions about scope, responsibility and useful detail.
A North Vancouver review raises the same question from another direction
We encountered the master-plan question directly in correspondence with the District of North Vancouver Fire and Rescue Services.
For the mixed-use building under review, several small commercial units were not being treated as occupancies requiring independent Fire Safety Plans. Instead, their building information was expected to be incorporated into the base-building Fire Safety Plan. Missing unit numbers, wall separations and pull stations were specifically identified as making the submitted plan an incomplete depiction of the building.
We then asked how that expectation would scale to a much larger multi-tenant property. Would the owner’s Fire Safety Plan still be expected to incorporate the layouts and systems of dozens, or potentially hundreds, of individual tenants?
The inspector indicated that it would, describing the Fire Safety Plan company’s scope as creating and submitting a full and accurate Fire Safety Plan of the building and directing us to the District’s published Fire Safety Plan guidelines and drawing examples.
The response is useful because it separates two questions that are often conflated.
The harder question is not whether the tenant exists on the drawing. It is what level of tenant detail materially improves the building’s Fire Safety Plan.
Materiality may be more useful than simply asking who occupies the space
A change of business name does not necessarily change the building’s fire-safety strategy. A change from an ordinary office or retail use to an occupancy introducing substantially different hazards, occupant loads, egress conditions or fire-protection systems can.
That suggests a more useful test for tenant information in a master plan: does the information materially affect emergency procedures, firefighter response, egress, hazards, fire separations, shared fire-protection systems, supervisory responsibilities or another element the Fire Safety Plan is intended to address?
Ontario’s Fire Code provides a useful expression of the underlying concept. Division B, Sentence 2.8.2.1.(4) requires a Fire Safety Plan to be reviewed as often as necessary, but at least every 12 months, and revised as necessary to account for changes in the use or other characteristics of the building or premises.
The requirement is not that a Fire Safety Plan become a continuously updated architectural record of every inconsequential physical or commercial change. The question is whether the information affects the fire-safety planning required for that building or premises.
Then there is the opposite question
So far, we have asked how much tenant information belongs in the base-building Fire Safety Plan.
The reverse question is equally important: how much base-building information belongs in the tenant Fire Safety Plan?
This is where our experience across AHJs becomes particularly relevant.
In Toronto, we have repeatedly been directed to remove overlapping information between tenant and base-building Fire Safety Plans.
Elsewhere in Ontario, we have been directed to include substantial base-building information in tenant plans, including detailed fire alarm information, complete site plans, fire department access routes and private hydrants.
Those are different expectations about how the documents should be prepared.
A more self-contained tenant plan can provide substantial information without requiring the user to locate another document. Reducing overlap can avoid maintaining multiple versions of the same information. Both considerations can be reasonable, and the reviewing AHJ may have established how it expects that balance to be struck.
It is important not to overread these examples. Toronto’s direction on overlap does not, by itself, tell us where every category of information must ultimately live. Vancouver’s published hierarchy does not say that overlap is prohibited. The District of North Vancouver correspondence addressed how tenant information should be represented in the base-building plan, not how much base-building content should be reproduced in a separate tenant plan.
Local knowledge is not national knowledge
There is an interesting trap in Fire Safety Plan work.
A consultant working repeatedly with one AHJ can develop an excellent understanding of exactly what that jurisdiction expects. That is valuable expertise. It is not necessarily a national rule.
If we prepared Fire Safety Plans exclusively in Toronto, years of submissions, comments and approvals could make Toronto’s expectations second nature. Move the same project team into another Ontario municipality and some of those assumptions may no longer apply, despite both jurisdictions administering the Ontario Fire Code. Move into another province and another layer changes again.
That does not make one approach right and another wrong. It means knowing the Fire Code and knowing how an AHJ expects it to be applied to a particular type of Fire Safety Plan are different forms of knowledge.
For a consultant working predominantly in one jurisdiction, those two forms of knowledge can eventually feel almost indistinguishable. National work forces the distinction back into view.
So, does a tenant need its own Fire Safety Plan?
Sometimes.
But the better analysis begins with a sequence of questions.
- Would the tenancy independently trigger Fire Safety Plan requirements under the applicable Fire Code?
- If it does, can those requirements be adequately addressed within the building’s existing Fire Safety Plan, or is a separate tenant plan appropriate or expected?
- What systems, hazards, people and procedures does the tenant actually control?
- What responsibilities have been allocated between the parties through the operating and lease arrangements?
- What tenant information needs to exist in the base-building Fire Safety Plan?
- What base-building information does the tenant need for its own emergency procedures?
- Where multiple plans exist, what information needs to overlap and what information is better maintained in one authoritative location?
- How does the reviewing AHJ expect those plans to work together?
A 900-square-foot nail salon, a restaurant, a two-storey retailer and a 150,000-square-foot department store should not necessarily produce identical answers.
Consistency does not necessarily mean identical plans
There may not be one Fire Safety Plan architecture that can be applied uniformly to every multi-tenant building in Canada.
Buildings differ. Occupancies differ. Lease structures differ. Fire-protection systems differ. Provincial requirements differ. And AHJs may have different expectations for how tenant and base-building Fire Safety Plans should interact.
For national property owners and operators, consistency therefore does not necessarily mean submitting the same Fire Safety Plan architecture everywhere.
The applicable Fire Code needs to be understood. The building needs to be understood. The tenancy needs to be understood. The division of responsibilities needs to be understood. And the expectations of the reviewing AHJ need to be understood.
The difficult part is knowing which conclusions come from the Fire Code, which come from the building and its operating structure, and which come from the expectations of the AHJ.
A Fire Safety Plan template can tell someone what information to collect. The Fire Code can tell them what requirements apply.
Neither necessarily tells them where every piece of information belongs when multiple parties, occupancies and Fire Safety Plans intersect within the same building.
And that is where what looked like a simple question becomes technical very quickly.
About the Author
Dylan Dufort
President
Fire Plan Strategies
Dylan Dufort is President of Fire Plan Strategies, a national fire safety planning company he has led since 2018. Prior to Fire Plan Strategies, Dylan served for 14 years as a firefighter with the City of Winnipeg. He holds an MBA from the Ivey Business School at Western University. His work combines frontline fire-service experience with the practical challenges of developing Fire Safety Plans across Canadian jurisdictions and working with authorities having jurisdiction across the country.
Research & References
Sources and reference documents
Ontario Fire Code, O. Reg. 213/07, Division B, Section 2.8 – Emergency Planning
Vancouver Fire Rescue Services, Bulletin 2026-001-FI – Fire Safety Plans, April 2, 2026
City of Vancouver, Fire Safety Plan Template
District of North Vancouver Fire & Rescue Services, Example Fire Safety Plan Drawings
City of Toronto, published commercial lease template – 540 Cedarvale Avenue
Direct correspondence with District of North Vancouver Fire & Rescue Services, Lieutenant – Public Safety, regarding tenant information in a mixed-use Fire Safety Plan
Project correspondence reviewed by Fire Plan Strategies
Practice note
References to AHJ comments, plan-review direction and project experience in this commentary reflect Fire Plan Strategies’ experience and should not be interpreted as published policies of the respective authorities having jurisdiction unless a published source is specifically identified. Published requirements and guidance are identified and cited separately. Requirements may vary by jurisdiction, project, building and circumstances. Always confirm requirements with the applicable AHJ.
Fire Plan Strategies